Пром . система измерения положения PMI104-F90-IU-V1 pepperl-fuchs

Производитель:Pepperl+Fuchs

Запросить цену
Analog output
Output type 1 current output: 4 ... 20 mA
1 voltage output: 0 ... 10 V
Load resistor current output: ≤ 400 Ω
voltage output: ≥ 1000 Ω
Short-circuit protection voltage output: pulsing
Compliance with standards and directives
Standard conformity

Standards EN 60947-5-2:2007
IEC 60947-5-2:2007
EN 60947-5-7:2003
IEC 60947-5-7:2003
Approvals and certificates
EAC conformity TR CU 020/2011
UL approval cULus Listed, General Purpose, Class 2 Power Source
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type 4-pin, M12 x 1 connector
Degree of protection IP67
Material

Housing ABS

Target mild steel, e. g. 1.0037, SR235JR (formerly St37-2)

Технические данные

General specifications
Switching element function analog, current or voltage output
Object distance 0.5 ... 3 mm , recommended: 2 mm
Measurement range 0 ... 104 mm
Linearity range 1 ... 103 mm
Nominal ratings
Operating voltage 18 ... 30 V DC
Reverse polarity protection reverse polarity protected
Linearity error within measuring range: ± 0.8 mm
within linearity range: ± 0.4 mm
Repeat accuracy ± 0.1 mm
Resolution 125 µm
Temperature drift ± 0.5 mm (-25 °C ... 70 °C)
No-load supply current ≤ 40 mA
Operating voltage indicator LED green
Functional safety related parameters
MTTFd 320 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %